A Current-sensor-free incremental conductance single cell MPPT

หน่วยงาน Central Queensland University, Australia

รายละเอียด

ชื่อเรื่อง : A Current-sensor-free incremental conductance single cell MPPT
นักวิจัย : Wolfs, Peter J. , Li, Q. (Quan)
คำค้น : Photovoltaic power generation. , TBA , 660205 Solar-photoelectric , 290901 Electrical Engineering , Solar energy. , Electric vehicles. , Photovoltaic -- Maximum power tracker
หน่วยงาน : Central Queensland University, Australia
ผู้ร่วมงาน : -
ปีพิมพ์ : 2549
อ้างอิง : http://hdl.cqu.edu.au/10018/7508 , 1424497177 , dest1-20070417-174759 , cqu:342 ,
ที่มา : Wolfs, P and Li, Q., (2006), "A Current-Sensor-Free Incremental Conductance Single Cell MPPT". PESC06, 37th IEEE Power Electronic Specialist Conference, 18-22 June 2006, Jeju, Korea, IEEE, New York.
ความเชี่ยวชาญ : -
ความสัมพันธ์ : PESC06 : 2006 37th IEEE Power Electronics Specialists Conference New York, N.Y. : IEEE, 2006. p.117-123 3337 pages 1424497177 , aCQUIRe [electronic resource] : Central Queensland University Institutional Repository.
ขอบเขตของเนื้อหา : -
บทคัดย่อ/คำอธิบาย :

A Maximum Power Point Tracker has been previously developed for a single high performance GaAs solar cell for hybrid and electric vehicle applications. This paper presents a new Maximum Power Point Tracking (MPPT) control algorithm which is based on the Incremental Conductance (IncCond) method but does not require any current sensing devices. In this new algorithm, the condition for the Maximum Power Point (MPP) operation can be established from the solar cell voltage and the converter switching duty ratio alone. The method can also be readily applied to any load type where power increases monotonically with voltage. A solar cell model for the triple junction cell is also thoroughly discussed. This model is used in the simulation circuit and the results for the new MPPT method are provided. Finally, a solar cell simulator and a 600-mW buck converter switching at 20 kHz controlled by Texas Instrument MSP430 microprocessor are used as the test platform for the new IncCond MPPT algorithm. The experimental results show that the proposed MPPT algorithm has secured a 1.5-ms response time due to illumination changes.

บรรณานุกรม :
Wolfs, Peter J. , Li, Q. (Quan) . (2549). A Current-sensor-free incremental conductance single cell MPPT.
    กรุงเทพมหานคร : Central Queensland University, Australia.
Wolfs, Peter J. , Li, Q. (Quan) . 2549. "A Current-sensor-free incremental conductance single cell MPPT".
    กรุงเทพมหานคร : Central Queensland University, Australia.
Wolfs, Peter J. , Li, Q. (Quan) . "A Current-sensor-free incremental conductance single cell MPPT."
    กรุงเทพมหานคร : Central Queensland University, Australia, 2549. Print.
Wolfs, Peter J. , Li, Q. (Quan) . A Current-sensor-free incremental conductance single cell MPPT. กรุงเทพมหานคร : Central Queensland University, Australia; 2549.