| ชื่อเรื่อง | : | Comparison of two NIR systems for quantifying kaolinite in Weipa bauxites |
| นักวิจัย | : | McArthur, Luke. , Greensill, Colin Victor. |
| คำค้น | : | Bauxite. , Resourcing Queensland , Near infrared spectroscopy , Kaolinite. , 640403 First stage treatment of ores and minerals , 299904 Engineering/Technology Instrumentation , 260101 Mineralogy and Crystallography , Kaolinite -- Bauxite -- Near infrared -- Mineral -- Signal to noise -- 6500 -- MPA |
| หน่วยงาน | : | Central Queensland University, Australia |
| ผู้ร่วมงาน | : | - |
| ปีพิมพ์ | : | 2550 |
| อ้างอิง | : | http://hdl.cqu.edu.au/10018/5110 , dest1-20071101-133151 , cqu:2255 , http://acquire.cqu.edu.au:8080/vital/access/manager/Repository/cqu:2255 , http://dx.doi.org/doi:10.1088/0957-0233/18/11/029 |
| ที่มา | : | McArthur, L & Greensill, C 2007, "Comparison of two NIR systems for quantifying kaolinite in Weipa bauxites", Measurement Science and Technology, vol, 18, no. 11, pp.3463-3470. http://dx.doi.org/doi:10.1088/0957-0233/18/11/029 |
| ความเชี่ยวชาญ | : | - |
| ความสัมพันธ์ | : | Measurement Science and Technology. UK : Institute of Physics, 2007. vol 18 no. 11 p. 3463-3470 8 pages Refereed 0957-0233 , aCQUIRe [electronic resource] : Central Queensland University Institutional Repository. |
| ขอบเขตของเนื้อหา | : | - |
| บทคัดย่อ/คำอธิบาย | : | Two laboratory-based near infrared systems were compared for the purpose of quantifying kaolinite within Weipa bauxites. The two systems were based on different instrument technologies, a Bruker MPA (multi-purpose analyser) FTNIR (Fourier transform near infrared) instrument, and a Foss Model 6500 pre-dispersive grating instrument. Systems were compared in terms of accuracy, robustness, sample throughput and ease of use. The MPA-based system was superior in terms of accuracy (root mean squared error of prediction (RMSEP) = 0.88%m/m), throughput and ease of use. The Model 6500 had an advantage of offering the most robust measurement with greater time stability and lower errors in repeated and repacked measurements. However, addition of a small number of temporally displaced and repacked samples in the calibration set improved robustness of the MPA system, matching the Model 6500. |
| บรรณานุกรม | : |
McArthur, Luke. , Greensill, Colin Victor. . (2550). Comparison of two NIR systems for quantifying kaolinite in Weipa bauxites.
กรุงเทพมหานคร : Central Queensland University, Australia. McArthur, Luke. , Greensill, Colin Victor. . 2550. "Comparison of two NIR systems for quantifying kaolinite in Weipa bauxites".
กรุงเทพมหานคร : Central Queensland University, Australia. McArthur, Luke. , Greensill, Colin Victor. . "Comparison of two NIR systems for quantifying kaolinite in Weipa bauxites."
กรุงเทพมหานคร : Central Queensland University, Australia, 2550. Print. McArthur, Luke. , Greensill, Colin Victor. . Comparison of two NIR systems for quantifying kaolinite in Weipa bauxites. กรุงเทพมหานคร : Central Queensland University, Australia; 2550.
|