ridm@nrct.go.th   ระบบคลังข้อมูลงานวิจัยไทย   รายการโปรดที่คุณเลือกไว้

Impact of resolution on NIR PLS calibration of kaolinite content in Weipa Bauxite

หน่วยงาน Central Queensland University, Australia

รายละเอียด

ชื่อเรื่อง : Impact of resolution on NIR PLS calibration of kaolinite content in Weipa Bauxite
นักวิจัย : McArthur, Luke. , Greensill, Colin Victor.
คำค้น : TBA , 640202 Aluminium ores , 249903 Instruments and Techniques , Kaolinite. , NIRS Bauxite Weipa
หน่วยงาน : Central Queensland University, Australia
ผู้ร่วมงาน : -
ปีพิมพ์ : 2550
อ้างอิง : http://hdl.cqu.edu.au/10018/7062 , , cqu:206 ,
ที่มา : McArthur, L & Greensill, C 2007 'Impact of resolution on NIR PLS calibration of kaolinite content in Weipa Bauxite', Measurement Science and Technology, vol. 18, no. 5, pp. 1343-1347.
ความเชี่ยวชาญ : -
ความสัมพันธ์ : Measurement Science and Technology. UK. : IOP, 2007. vol 18, issue 5 p. 1343-1347 4 pages Refereed 0957-0233 (online) , aCQUIRe [electronic resource] : Central Queensland University Institutional Repository.
ขอบเขตของเนื้อหา : -
บทคัดย่อ/คำอธิบาย :

The impact of spectral resolution on the quantification of kaolinite in Weipa bauxite was assessed with a view to the development of a quantitative tool for routine onsite use. Spectral data (calibration set = 204 samples, prediction set = 60 samples) were acquired at five resolution settings (2, 4, 8, 16, and 32 cm-1 ) using a Bruker MPA Fourier Transform NIR (FTNIR) instrument. Visually, the increase in resolution from 32cm-1 to 8cm-1 yielded an apparent increase in spectral feature definition whilst further increase in resolution (4 or 2cm-1) gave no additional benefit. PLS models, using identical data-treatments and spectral windows, were developed for each resolution setting. Root mean squared errors of prediction (RMSEP) were not significantly different for the resolutions 2,4,8 and 16cm-1 whilst models built at the 32cm-1 had RMSEPs significantly 4-5% worse than the other resolutions. The results demonstrated that PLS calibration of kaolinite content in Weipa bauxite was nominally affected by resolution with no predictive gain demonstrated beyond 16cm-1.

บรรณานุกรม :
McArthur, Luke. , Greensill, Colin Victor. . (2550). Impact of resolution on NIR PLS calibration of kaolinite content in Weipa Bauxite.
    กรุงเทพมหานคร : Central Queensland University, Australia.
McArthur, Luke. , Greensill, Colin Victor. . 2550. "Impact of resolution on NIR PLS calibration of kaolinite content in Weipa Bauxite".
    กรุงเทพมหานคร : Central Queensland University, Australia.
McArthur, Luke. , Greensill, Colin Victor. . "Impact of resolution on NIR PLS calibration of kaolinite content in Weipa Bauxite."
    กรุงเทพมหานคร : Central Queensland University, Australia, 2550. Print.
McArthur, Luke. , Greensill, Colin Victor. . Impact of resolution on NIR PLS calibration of kaolinite content in Weipa Bauxite. กรุงเทพมหานคร : Central Queensland University, Australia; 2550.