ridm@nrct.go.th   ระบบคลังข้อมูลงานวิจัยไทย   รายการโปรดที่คุณเลือกไว้

Rural healthcare improvement through development of low-cost nano-biosensors

หน่วยงาน Central Queensland University, Australia

รายละเอียด

ชื่อเรื่อง : Rural healthcare improvement through development of low-cost nano-biosensors
นักวิจัย : Preethichandra, Daluwathu M. G. , Ekanayake, Mala. , Kaneto, K. (Keiichi)
คำค้น : LIBRARY OF CONGRESS NEEDED , 850603 Energy Systems Analysis. , 850703 Industrial Energy Conservation and Efficiency. , 090401 Carbon Capture Engineering (excl. Sequestration). , 090607 Power and Energy Systems Engineering (excl. Renewable Power). , 090407 Process Control and Simulation. , Glucose Oxidas -- Polypyrrol -- Pulsed deposition -- Electro phoretic deposition -- Biosensor. , Conference Paper. Full Paper (Refereed)
หน่วยงาน : Central Queensland University, Australia
ผู้ร่วมงาน : -
ปีพิมพ์ : 2555
อ้างอิง : https://www.engineersaustralia.org.au/sites/default/files/shado/Divisions/Queensland%20Division/Events/2012/proceedings_1.pdf , http://hdl.cqu.edu.au/10018/938079
ที่มา : Preethichandra, DMG, Mala Ekanayake, EMI & Kaneto, K 2012, 'Rural Healthcare Improvement Through Development of Low-Cost Nano-Biosensors', paper presented to the Central Region Engineering Conference, Central Queensland University, Rockhampton, Queensland, 10th-11th August, https://www.engineersaustralia.org.au/sites/default/files/shado/Divisions/Queensland%20Division/Events/2012/proceedings_1.pdf
ความเชี่ยวชาญ : -
ความสัมพันธ์ : Central Region Engineering Conference 2012 proceedings,10-11 August, 2012, Rockhampton, Queensland. Rockhampton, Queensland : Engineers Australia, 2012. p. 59-62 4 pages Refereed , ACQUIRE [electronic resource] : Central Queensland University Institutional Repository.
ขอบเขตของเนื้อหา : -
บทคัดย่อ/คำอธิบาย :

This paper presents a method of developing a highly corrugated polypyrrole nano-biosensor for blood glucce measurements. The fabrication method derived decreases the cost of production significantly as the amount of noble metals used is minimized. The sensitivity achieved was 325mA/M/cm2 and the linear range was 60mM.

บรรณานุกรม :
Preethichandra, Daluwathu M. G. , Ekanayake, Mala. , Kaneto, K. (Keiichi) . (2555). Rural healthcare improvement through development of low-cost nano-biosensors.
    กรุงเทพมหานคร : Central Queensland University, Australia.
Preethichandra, Daluwathu M. G. , Ekanayake, Mala. , Kaneto, K. (Keiichi) . 2555. "Rural healthcare improvement through development of low-cost nano-biosensors".
    กรุงเทพมหานคร : Central Queensland University, Australia.
Preethichandra, Daluwathu M. G. , Ekanayake, Mala. , Kaneto, K. (Keiichi) . "Rural healthcare improvement through development of low-cost nano-biosensors."
    กรุงเทพมหานคร : Central Queensland University, Australia, 2555. Print.
Preethichandra, Daluwathu M. G. , Ekanayake, Mala. , Kaneto, K. (Keiichi) . Rural healthcare improvement through development of low-cost nano-biosensors. กรุงเทพมหานคร : Central Queensland University, Australia; 2555.