| ชื่อเรื่อง | : | Feasibility of thermal energy storage systems in an institutional building in subtropical climates in Australia |
| นักวิจัย | : | Rahman, Md. M. , Rasul, Mohammad. , Khan, Mohammad Masud Kamal. |
| คำค้น | : | Heat storage devices , Applied research. , 850603 Energy Systems Analysis. , 850701 Commercial Energy Conservation and Efficiency. , 090607 Power and Energy Systems Engineering (excl. Renewable Power) , 091305 Energy Generation, Conversion and Storage Engineering. , Cooling. , Electrical engineering. , Thermal energy storage -- Technical and economical feasibility -- Development of building model -- Cooling load profiles -- Subtropical climates |
| หน่วยงาน | : | Central Queensland University, Australia |
| ผู้ร่วมงาน | : | - |
| ปีพิมพ์ | : | 2554 |
| อ้างอิง | : | http://hdl.cqu.edu.au/10018/915935 |
| ที่มา | : | Rahman, M, Rasul, M & Khan, M 2011, 'Feasibility of thermal energy storage systems in an institutional building in subtropical climates in Australia', Applied Thermal Engineering, vol. 31, no.14-15, pp.2943-2950, http://dx.doi.org/10.1016/j.applthermaleng.2011.05.025 |
| ความเชี่ยวชาญ | : | - |
| ความสัมพันธ์ | : | Applied thermal engineering. Netherlands : Elsevier, 2011. Vol. 31, no. 14-15 (October 2011), p. 2943-2950 8 pages Refereed 1359-4311 , ACQUIRE [electronic resource] : Central Queensland University Institutional Repository. |
| ขอบเขตของเนื้อหา | : | - |
| บทคัดย่อ/คำอธิบาย | : | Thermal energy storage is (TES) a preferred demand side management (DSM) technology for shifting cooling load demand from peak hour to off-peak hour in the heating, ventilating and air conditioning (HVAC) industry. In this study, the technical and economical feasibility of introducing TES systems in a building in subtropical Central Queensland (Australia) is presented. Firstly, the cooling load profile of existing systems is simulated using building simulation software DesignBuilder (DB) and verified with on-site measured data. Then, using the verified simulation technique, the technical and economical feasibility of TES systems are analysed for both full and partial storage scenarios. The results show that the full and partial chilled storage systems can save up to 61.19% and 50.26% respectively of the electricity cost required for cooling when compared with the conventional system in subtropical climate. |
| บรรณานุกรม | : |
Rahman, Md. M. , Rasul, Mohammad. , Khan, Mohammad Masud Kamal. . (2554). Feasibility of thermal energy storage systems in an institutional building in subtropical climates in Australia.
กรุงเทพมหานคร : Central Queensland University, Australia. Rahman, Md. M. , Rasul, Mohammad. , Khan, Mohammad Masud Kamal. . 2554. "Feasibility of thermal energy storage systems in an institutional building in subtropical climates in Australia".
กรุงเทพมหานคร : Central Queensland University, Australia. Rahman, Md. M. , Rasul, Mohammad. , Khan, Mohammad Masud Kamal. . "Feasibility of thermal energy storage systems in an institutional building in subtropical climates in Australia."
กรุงเทพมหานคร : Central Queensland University, Australia, 2554. Print. Rahman, Md. M. , Rasul, Mohammad. , Khan, Mohammad Masud Kamal. . Feasibility of thermal energy storage systems in an institutional building in subtropical climates in Australia. กรุงเทพมหานคร : Central Queensland University, Australia; 2554.
|