Energy conservation measures in an institutional building in sub-tropical climate in Australia

หน่วยงาน Central Queensland University, Australia

รายละเอียด

ชื่อเรื่อง : Energy conservation measures in an institutional building in sub-tropical climate in Australia
นักวิจัย : Rahman, Md. M. , Rasul, Mohammad. , Khan, Mohammad Masud Kamal.
คำค้น : Energy conservation. , Applied research. , 850603 Energy Systems Analysis. , 850701 Commercial Energy Conservation and Efficiency. , 090607 Power and Energy Systems Engineering (excl. Renewable Power) , Power resources , Buildings , Energy conservation measures -- Hot-humid climate -- DesignBuilder -- Building energy simulation -- Thermal comfort index
หน่วยงาน : Central Queensland University, Australia
ผู้ร่วมงาน : -
ปีพิมพ์ : 2553
อ้างอิง : http://hdl.cqu.edu.au/10018/56160
ที่มา : Rahman, M, Rasul, M & Khan, M 2010, 'Energy conservation measures in an institutional building in sub-tropical climate in Australia', Applied Energy, vol. 87, no. 10, pp. 2994-3004, http://dx.doi.org/10.1016/j.apenergy.2010.04.005
ความเชี่ยวชาญ : -
ความสัมพันธ์ : Applied energy. Netherlands : Elsevier, 2010. Vol. 87, no. 10 (October 2010), p. 2994-3004 11 pages Refereed 0306-2619 , ACQUIRE [electronic resource] : Central Queensland University Institutional Repository.
ขอบเขตของเนื้อหา : -
บทคัดย่อ/คำอธิบาย :

In this study, various energy conservation measures (ECMs) on heating, ventilating and air conditioning (HVAC) and lighting systems for a four-storied institutional building in subtropical (hot and humid climate) Queensland, Australia are evaluated using the simulation software called DesignBuilder (DB). Base case scenario of energy consumption profiles of existing systems are analysed and simulated first then, the simulated results are verified by on-site measured data. Three categories of ECMs, namely major investment ECMs (variable air volume (VAV) systems against constant air volume (CAV); and low coefficient of performance (COP) chillers against high COP chillers); minor investment ECMs (photo electric dimming control system against general lighting, and double glazed low emittance windows against single glazed windows) and zero investment ECMs (reset heating and cooling set point temperatures) are evaluated. It is found that the building considered in this study can save up to 41.87% energy without compromising occupancies thermal comfort by implementing the above mentioned ECMs into the existing system.

บรรณานุกรม :
Rahman, Md. M. , Rasul, Mohammad. , Khan, Mohammad Masud Kamal. . (2553). Energy conservation measures in an institutional building in sub-tropical climate in Australia.
    กรุงเทพมหานคร : Central Queensland University, Australia.
Rahman, Md. M. , Rasul, Mohammad. , Khan, Mohammad Masud Kamal. . 2553. "Energy conservation measures in an institutional building in sub-tropical climate in Australia".
    กรุงเทพมหานคร : Central Queensland University, Australia.
Rahman, Md. M. , Rasul, Mohammad. , Khan, Mohammad Masud Kamal. . "Energy conservation measures in an institutional building in sub-tropical climate in Australia."
    กรุงเทพมหานคร : Central Queensland University, Australia, 2553. Print.
Rahman, Md. M. , Rasul, Mohammad. , Khan, Mohammad Masud Kamal. . Energy conservation measures in an institutional building in sub-tropical climate in Australia. กรุงเทพมหานคร : Central Queensland University, Australia; 2553.