ridm@nrct.go.th   ระบบคลังข้อมูลงานวิจัยไทย   รายการโปรดที่คุณเลือกไว้

An analysis of the indoor air quality and mould growth in a multi-zone building

หน่วยงาน Central Queensland University, Australia

รายละเอียด

ชื่อเรื่อง : An analysis of the indoor air quality and mould growth in a multi-zone building
นักวิจัย : Chowdhury, Ashfaque Ahmed. , Rasul, Mohammad. , Khan, Mohammad Masud Kamal.
คำค้น : Applied research. , 850704 Residential Energy Conservation and Efficiency. , 091305 Energy Generation, Conversion and Storage Engineering. , 090702 Environmental Engineering Modelling. , 090703 Environmental Technologies. , Air quality , Molds (Fungi) , Building simulation -- Indoor air quality -- Mould growth
หน่วยงาน : Central Queensland University, Australia
ผู้ร่วมงาน : -
ปีพิมพ์ : 2552
อ้างอิง : http://hdl.cqu.edu.au/10018/45461 , 10.1007/s11267-009-9244-8
ที่มา : Chowdhury, A, Rasul, M & Khan, M 2009, 'An analysis of the indoor air quality and mould growth in a multi-zone building', Water Air Soil Pollution: Focus, vol. 9, no. 5-6, pp. 517-527. http://dx.doi.org/10.1007/s11267-009-9244-8 (viewed 4/6/10)
ความเชี่ยวชาญ : -
ความสัมพันธ์ : Water, air and soil pollution : focus. Netherlands. : Springer, 2009. vol. 9, no. 5-6 (2009), p. 517-527 11 pages Refereed 1567-7230 1573-2940 (online) , ACQUIRE [electronic resource] : Central Queensland University Institutional Repository.
ขอบเขตของเนื้อหา : -
บทคัดย่อ/คำอธิบาย :

The effects of poor indoor air quality and mould growth in working environment are major problems in built environment, and there is a need to look for improvement of the health, comfort and productivity of the building occupants. Airborne mould sampling studies were conducted in a reference building located in Rockhampton, Central Queensland, Australia. Both indoor culturable and mould spore levels were observed. It was found through the indoor–outdoor ratios of the species that indoor concentrations are mostly related to the outdoor mould levels. The moulds differ in their relative humidity and temperature requirements to support surface growth. Indoor humidity has a significant effect on occupants comfort, perceived air quality, occupants’ health, building durability, emissions and energy efficiency. Practical hygrothermal simulation models are employed to analyse the combined heat and moisture behaviour within the built environment. A review of the current modelling options available to predict building performance based on energy and mass transport simulation is presented, and then a case study is presented with the assessment of indoor built environment to avoid mould problem.

บรรณานุกรม :
Chowdhury, Ashfaque Ahmed. , Rasul, Mohammad. , Khan, Mohammad Masud Kamal. . (2552). An analysis of the indoor air quality and mould growth in a multi-zone building.
    กรุงเทพมหานคร : Central Queensland University, Australia.
Chowdhury, Ashfaque Ahmed. , Rasul, Mohammad. , Khan, Mohammad Masud Kamal. . 2552. "An analysis of the indoor air quality and mould growth in a multi-zone building".
    กรุงเทพมหานคร : Central Queensland University, Australia.
Chowdhury, Ashfaque Ahmed. , Rasul, Mohammad. , Khan, Mohammad Masud Kamal. . "An analysis of the indoor air quality and mould growth in a multi-zone building."
    กรุงเทพมหานคร : Central Queensland University, Australia, 2552. Print.
Chowdhury, Ashfaque Ahmed. , Rasul, Mohammad. , Khan, Mohammad Masud Kamal. . An analysis of the indoor air quality and mould growth in a multi-zone building. กรุงเทพมหานคร : Central Queensland University, Australia; 2552.