| ชื่อเรื่อง | : | Filshie clip closure : determination of closure through the analysis of x-rays |
| นักวิจัย | : | Clegg, Richard E. |
| คำค้น | : | Contraceptives. , TBA , Sterilization of women. , Obstetrics. , Generative organs. , Women , Biomedical engineering. , Medical personnel , 730201 Women's health , 730116 Reproductive system and disorders , 321014 Obstetrics and Gynaecology , 291501 Clinical Engineering , Female contraception -- Fallopian tube -- Medical negligence -- Tubal occlusion -- Filshie method |
| หน่วยงาน | : | Central Queensland University, Australia |
| ผู้ร่วมงาน | : | - |
| ปีพิมพ์ | : | 2551 |
| อ้างอิง | : | http://hdl.cqu.edu.au/10018/22443 , http://ezproxy.cqu.edu.au/login?url=http://dx.doi.org/10.1016/j.jflm.2008.05.008 , cqu:3598 |
| ที่มา | : | Clegg, R 2008, "Filshie Clip Closure: Determination of closure through the analysis of x-rays", Journal of Forensic and Legal Medicine, vol.15, no.8, pp. 510-515. |
| ความเชี่ยวชาญ | : | - |
| ความสัมพันธ์ | : | Journal of forensic and legal medicine. Oxford, UK. : Elsevier, 2008. Vol.15, issue 8 (November 2008), p. 510-515 6 pages Refereed 1752-928X 1752-928X (online) , aCQUIRe [electronic resource] : Central Queensland University Institutional Repository. |
| ขอบเขตของเนื้อหา | : | - |
| บทคัดย่อ/คำอธิบาย | : | The Filshie method is a tubal occlusion method commonly used to prevent pregnancy. In medical negligence cases where it is suspected that closure of a Filshie clip may be faulty, lawyers may call on expert surgeons to assess whether or not a clip is closed on the basis of visual examination of the x-rays. However, it is not uncommon for experts to disagree. The aim of this work was to reduce the uncertainty in determining whether or not Filshie clips had been correctly closed. An estimate of the error in the estimate of the clip height was made by propagating measurement errors through a mathematical model. The effects of angle of presentation of the clip, digitisation of the image and resolution of the measurements were studied and the method was applied to two cases. The analysis indicated that measurement errors were least when the digitisation of the image was at 600dpi, angle of presentation of the clip was less than 40 and the measurements could be made to an accuracy of 1 pixel. Under these conditions it was possible to determine clip closure height with an error of less than 0.2 mm. |
| บรรณานุกรม | : |
Clegg, Richard E. . (2551). Filshie clip closure : determination of closure through the analysis of x-rays.
กรุงเทพมหานคร : Central Queensland University, Australia. Clegg, Richard E. . 2551. "Filshie clip closure : determination of closure through the analysis of x-rays".
กรุงเทพมหานคร : Central Queensland University, Australia. Clegg, Richard E. . "Filshie clip closure : determination of closure through the analysis of x-rays."
กรุงเทพมหานคร : Central Queensland University, Australia, 2551. Print. Clegg, Richard E. . Filshie clip closure : determination of closure through the analysis of x-rays. กรุงเทพมหานคร : Central Queensland University, Australia; 2551.
|