| ชื่อเรื่อง | : | Buildings energy simulation using energy express a case study on sub-tropical Central Queensland University (CQU) buildings |
| นักวิจัย | : | Rahman, Mohammad. , Rasul, Mohammad. , Khan, Mohammad Masud Kamal. |
| คำค้น | : | Air conditioning , TBA , 660304 Energy systems analysis , 660504 Conservation and efficiency , 669999 Other (e.g. safety) , 291802 Heat and Mass Transfer Operations , 290901 Electrical Engineering , 299904 Engineering/Technology Instrumentation , Libraries , Buildings , Heating. , Building energy -- Hot-humid climate -- Energy conservation -- Energy simulation -- Variable air volume system |
| หน่วยงาน | : | Central Queensland University, Australia |
| ผู้ร่วมงาน | : | - |
| ปีพิมพ์ | : | 2549 |
| อ้างอิง | : | http://hdl.cqu.edu.au/10018/7998 , , cqu:506 , |
| ที่มา | : | Rahman, MM., Rasul, MG. & Khan, MMK. 2006, "Buildings Energy Simulation Using Energy Express: A Case Study on Sub-tropical Central Queensland University", Proceedings of the 3rd BSME - ASME International Conference on Thermal Engineering, 20th - 22th December, 2006 ,Dhaka, Bangladesh. |
| ความเชี่ยวชาญ | : | - |
| ความสัมพันธ์ | : | 3rd BSME-ASME International Conference on Thermal Engineering. Dhaka, Bangladesh : Bangladesh Society of Mechanical Enineers (BSME), 2006. 6 pages Refereed , aCQUIRe [electronic resource] : Central Queensland University Institutional Repository. |
| ขอบเขตของเนื้อหา | : | - |
| บทคัดย่อ/คำอธิบาย | : | The strategies of buildings energy management can be developed through energy audit, analysis and simulation. Currently, different end-users of CQU buildings such as heating, ventilating and air conditioning (HVAC) units, electrical appliances, etc do not take full advantage of local sub-tropical climatic conditions. Therefore, climate-responsive strategies need to be implemented in order to take full advantage of the positive climate attribute of sub-tropical climate regarding efficient energy management and conservation measures. This study is conducted on a three-story library building of CQU. HVAC systems were selected for practical operational energy conservation measures (ECM) to take advantages of hot and humid subtropical climate. A baseline energy consumption profile of the building is simulated using building energy simulation software called Energy Express (EE). The simulated results are then validated with energy audit and on-site metered data. The means to utilize environmental conditions to improve building energy efficiency is investigated. Variable air volume (VAV) system as an energy conservation option is investigated and compared with existing constant air volume (CAV) system. This study found that about 12% energy savings could be achieved by replacing CAV system with VAV system as an option for energy retrofitting, and hence recommended to CQU management for consideration. |
| บรรณานุกรม | : |
Rahman, Mohammad. , Rasul, Mohammad. , Khan, Mohammad Masud Kamal. . (2549). Buildings energy simulation using energy express a case study on sub-tropical Central Queensland University (CQU) buildings.
กรุงเทพมหานคร : Central Queensland University, Australia. Rahman, Mohammad. , Rasul, Mohammad. , Khan, Mohammad Masud Kamal. . 2549. "Buildings energy simulation using energy express a case study on sub-tropical Central Queensland University (CQU) buildings".
กรุงเทพมหานคร : Central Queensland University, Australia. Rahman, Mohammad. , Rasul, Mohammad. , Khan, Mohammad Masud Kamal. . "Buildings energy simulation using energy express a case study on sub-tropical Central Queensland University (CQU) buildings."
กรุงเทพมหานคร : Central Queensland University, Australia, 2549. Print. Rahman, Mohammad. , Rasul, Mohammad. , Khan, Mohammad Masud Kamal. . Buildings energy simulation using energy express a case study on sub-tropical Central Queensland University (CQU) buildings. กรุงเทพมหานคร : Central Queensland University, Australia; 2549.
|