| ชื่อเรื่อง | : | Air-breathing membraneless laminar flow-based fuel cell with flow-through anode |
| นักวิจัย | : | Shaegh, Seyed Ali Mousavi , Nguyen, Nam-Trung , Chan, Siew Hwa , Zhou, Weijiang |
| คำค้น | : | DRNTU::Engineering::Mechanical engineering::Power resources |
| หน่วยงาน | : | Nanyang Technological University, Singapore |
| ผู้ร่วมงาน | : | - |
| ปีพิมพ์ | : | 2554 |
| อ้างอิง | : | Shaegh, S. A. M., Nguyen, N. T., Chan, S. H., & Zhou, W. (2012). Air-breathing membraneless laminar flow-based fuel cell with flow-through anode. International Journal of Hydrogen Energy, 37(4), 3466-3476. , http://hdl.handle.net/10220/7685 , http://dx.doi.org/10.1016/j.ijhydene.2011.11.051 , 163852 |
| ที่มา | : | - |
| ความเชี่ยวชาญ | : | - |
| ความสัมพันธ์ | : | International journal of hydrogen energy |
| ขอบเขตของเนื้อหา | : | - |
| บทคัดย่อ/คำอธิบาย | : | This paper describes a detailed characterization of laminar flow-based fuel cell (LFFC) with air-breathing cathode for performance (fuel utilization and power density). The effect of flow-over and flow-through anode architectures, as well as operating conditions such as different fuel flow rates and concentrations on the performance of LFFCs was investigated. Formic acid with concentrations of 0.5 M and 1 M in a 0.5 M sulfuric acid solution as supporting electrolyte were exploited with varying flow rates of 20, 50, 100 and 200 μl/min. Because of the improved mass transport to catalytic active sites, the flow-through anode showed improved maximum power density and fuel utilization per single pass compared to flow-over planar anode. Running on 200 μl/min of 1 M formic acid, maximum power densities of 26.5 mW/cm2 and 19.4 mW/cm2 were obtained for the cells with flow-through and flow-over anodes, respectively. In addition, chronoamperometry experiment at flow rate of 100 μl/min with fuel concentrations of 0.5 M and 1 M revealed average current densities of 34.2 mA/cm2 and 52.3 mA/cm2 with average fuel utilization of 16.3% and 21.4% respectively for flow-through design. The flow-over design had the corresponding values of 25.1 mA/cm2 and 35.5 mA/cm2 with fuel utilization of 11.1% and 15.7% for the same fuel concentrations and flow rate. |
| บรรณานุกรม | : |
Shaegh, Seyed Ali Mousavi , Nguyen, Nam-Trung , Chan, Siew Hwa , Zhou, Weijiang . (2554). Air-breathing membraneless laminar flow-based fuel cell with flow-through anode.
กรุงเทพมหานคร : Nanyang Technological University, Singapore. Shaegh, Seyed Ali Mousavi , Nguyen, Nam-Trung , Chan, Siew Hwa , Zhou, Weijiang . 2554. "Air-breathing membraneless laminar flow-based fuel cell with flow-through anode".
กรุงเทพมหานคร : Nanyang Technological University, Singapore. Shaegh, Seyed Ali Mousavi , Nguyen, Nam-Trung , Chan, Siew Hwa , Zhou, Weijiang . "Air-breathing membraneless laminar flow-based fuel cell with flow-through anode."
กรุงเทพมหานคร : Nanyang Technological University, Singapore, 2554. Print. Shaegh, Seyed Ali Mousavi , Nguyen, Nam-Trung , Chan, Siew Hwa , Zhou, Weijiang . Air-breathing membraneless laminar flow-based fuel cell with flow-through anode. กรุงเทพมหานคร : Nanyang Technological University, Singapore; 2554.
|
