ridm@nrct.go.th   ระบบคลังข้อมูลงานวิจัยไทย   รายการโปรดที่คุณเลือกไว้

Sigma-delta receive beamformer based on cascaded reconstruction for ultrasound imaging application

หน่วยงาน Nanyang Technological University, Singapore

รายละเอียด

ชื่อเรื่อง : Sigma-delta receive beamformer based on cascaded reconstruction for ultrasound imaging application
นักวิจัย : Cheong, Jia Hao , Lam, Yvonne Ying Hung , Tiew, Kei Tee , Koh, Liang Mong
คำค้น : DRNTU::Engineering::Electrical and electronic engineering
หน่วยงาน : Nanyang Technological University, Singapore
ผู้ร่วมงาน : -
ปีพิมพ์ : 2551
อ้างอิง : Cheong, J. H., Lam, Y. H., Tiew, K. T., & Koh, L. M. (2008) Sigma-delta receive beamformer based on cascaded reconstruction for ultrasound imaging application. IEEE Transactions on Ultrasonics, Feroelectrics, and Frequency Control. 55(9), 1935-1946. , 0885-3010 , http://hdl.handle.net/10220/6268 , http://dx.doi.org/10.1109/TUFFC.885
ที่มา : -
ความเชี่ยวชาญ : -
ความสัมพันธ์ : IEEE transactions on ultrasonics, feroelectrics, and frequency control
ขอบเขตของเนื้อหา : -
บทคัดย่อ/คำอธิบาย :

A pre-delay reconstruction sigma-delta beamformer (SDBF) was recently proposed to achieve a higher level of integration in ultrasound imaging systems. Nevertheless, the high-order reconstruction filter used in each channel of SDBF makes the beamformer highly complex. The beamformer can be simplified by reconstructing the signal after the delay-andsum process with only one filter. However, this post-delay reconstruction-based design degrades image quality when dynamic focusing is performed. This paper shows that employing a simple pre-delay filter is sufficient to achieve similar performance as conventional pre-delay reconstruction SDBF, as long as the pre-delay filter provides the required pre-delay signalto- quantization noise ratio (SQNR). Based on this finding, we proposed a cascaded reconstruction beamformer that uses a boxcar filter as the pre-delay filter in each channel. Simulations using real phantom data demonstrate that the proposed beamforming method can achieve a contrast resolution comparable to that of the pre-delay reconstruction beamforming method. In addition, the hardware can be greatly simplified compared with the pre-delay reconstruction beamformers.

บรรณานุกรม :
Cheong, Jia Hao , Lam, Yvonne Ying Hung , Tiew, Kei Tee , Koh, Liang Mong . (2551). Sigma-delta receive beamformer based on cascaded reconstruction for ultrasound imaging application.
    กรุงเทพมหานคร : Nanyang Technological University, Singapore.
Cheong, Jia Hao , Lam, Yvonne Ying Hung , Tiew, Kei Tee , Koh, Liang Mong . 2551. "Sigma-delta receive beamformer based on cascaded reconstruction for ultrasound imaging application".
    กรุงเทพมหานคร : Nanyang Technological University, Singapore.
Cheong, Jia Hao , Lam, Yvonne Ying Hung , Tiew, Kei Tee , Koh, Liang Mong . "Sigma-delta receive beamformer based on cascaded reconstruction for ultrasound imaging application."
    กรุงเทพมหานคร : Nanyang Technological University, Singapore, 2551. Print.
Cheong, Jia Hao , Lam, Yvonne Ying Hung , Tiew, Kei Tee , Koh, Liang Mong . Sigma-delta receive beamformer based on cascaded reconstruction for ultrasound imaging application. กรุงเทพมหานคร : Nanyang Technological University, Singapore; 2551.