| ชื่อเรื่อง | : | Field-amplified sample injection and in-capillary derivatization for capillary electrophoretic analysis of metal ions in local wines |
| นักวิจัย | : | Santalad A. , Burakham R. , Srijaranai S. , Grudpan K. |
| คำค้น | : | - |
| หน่วยงาน | : | มหาวิทยาลัยเชียงใหม่ |
| ผู้ร่วมงาน | : | - |
| ปีพิมพ์ | : | 2550 |
| อ้างอิง | : | 0026265X , 10.1016/j.microc.2007.03.006 , MICJA , http://www.scopus.com/inward/record.url?eid=2-s2.0-34249321217&partnerID=40&md5=85549c4b3db694c851ba85facf8454b4 , http://cmuir.cmu.ac.th/handle/6653943832/5221 |
| ที่มา | : | - |
| ความเชี่ยวชาญ | : | - |
| ความสัมพันธ์ | : | - |
| ขอบเขตของเนื้อหา | : | - |
| บทคัดย่อ/คำอธิบาย | : | In-capillary derivatization and field-amplified sample injection (FASI) coupled to capillary zone electrophoresis (CZE) was evaluated for the analysis of metals (Co(II), Cu(II), Ni(II), and Fe(II)) using 2-(5-Nitro-2-Pyridylazo)-5-(N-Propyl-N-Sulfopropylamino)Phenol (Nitro-PAPS) as the derivatizing agent. For FASI, the optimum conditions were water as sample solvent, 1 s hydrodynamic injection (0.1 psi) of a water plug, 5 s of electrokinetic introduction (10 kV) of the sample. The in-capillary derivatization was successfully achieved with zone-passing strategy in order tandem injection of Nitro-PAPS reagent (0.5 psi, 7 s), a small water plug (0.1 psi, 1 s), and metal ion introduction (10 kV, 5 s). The solution of 45 mmol L- 1 borate pH 9.7 and 1.0 × 10- 5 mol L- 1 Nitro-PAPS containing 20% acetonitrile was used as the running buffer. The limit of detection obtained by the proposed method was lower than those from pre-capillary derivatization about 3-28 times. The recovery of the method was comparable to pre-capillary derivatization method. In-capillary derivatization-FASI-CZE was applied to analysis of metals in wine samples. The results were compared with those obtained by CZE with pre-capillary derivatization method and atomic absorption spectrometry (AAS). © 2007 Elsevier B.V. All rights reserved. |
| บรรณานุกรม | : |
Santalad A. , Burakham R. , Srijaranai S. , Grudpan K. . (2550). Field-amplified sample injection and in-capillary derivatization for capillary electrophoretic analysis of metal ions in local wines.
เชียงใหม่ : มหาวิทยาลัยเชียงใหม่ . Santalad A. , Burakham R. , Srijaranai S. , Grudpan K. . 2550. "Field-amplified sample injection and in-capillary derivatization for capillary electrophoretic analysis of metal ions in local wines".
เชียงใหม่ : มหาวิทยาลัยเชียงใหม่ . Santalad A. , Burakham R. , Srijaranai S. , Grudpan K. . "Field-amplified sample injection and in-capillary derivatization for capillary electrophoretic analysis of metal ions in local wines."
เชียงใหม่ : มหาวิทยาลัยเชียงใหม่ , 2550. Print. Santalad A. , Burakham R. , Srijaranai S. , Grudpan K. . Field-amplified sample injection and in-capillary derivatization for capillary electrophoretic analysis of metal ions in local wines. เชียงใหม่ : มหาวิทยาลัยเชียงใหม่ ; 2550.
|
