| ชื่อเรื่อง | : | Comparison of proteinuria determination by urine dipstick, spot urine protein creatinine index, and urine protein 24 hours in lupus patients |
| นักวิจัย | : | Chotayaporn T. , Kasitanon N. , Sukitawut W. , Louthrenoo W. |
| คำค้น | : | - |
| หน่วยงาน | : | มหาวิทยาลัยเชียงใหม่ |
| ผู้ร่วมงาน | : | - |
| ปีพิมพ์ | : | 2554 |
| อ้างอิง | : | 10761608 , 10.1097/RHU.0b013e318214bd18 , 21441821 , JCRHF , http://www.scopus.com/inward/record.url?eid=2-s2.0-79955072719&partnerID=40&md5=27b9deb50f1df93e0333943e68742998 , http://www.ncbi.nlm.nih.gov/pubmed/21441821 , http://cmuir.cmu.ac.th/handle/6653943832/2677 |
| ที่มา | : | - |
| ความเชี่ยวชาญ | : | - |
| ความสัมพันธ์ | : | - |
| ขอบเขตของเนื้อหา | : | - |
| บทคัดย่อ/คำอธิบาย | : | Background: A simple, convenient, and accurate method for detecting urine protein excretion in lupus nephritis is crucial. Objectives: The objectives of the study were to determine the sensitivity and the specificity of the qualitative urine dipstick test value to detect 0.50 g or greater of the quantitative 24-hour urine protein (24-hUP) in lupus patients, to evaluate an overall agreement of the dipstick test results and the magnitude of 24-hUP, and to examine the correlation between the spot urine protein creatinine index (S-UPCI) and the 24-hour UPCI with that of the 24-hUp. Methods: A prospective study was conducted in 92 patients with lupus. All dipstick test values from 5 dipstick assays (Bayer, Roche, Meditest USA, Standard Diagnostics, and Arkray) and the S-UPCI were obtained within 6 hours of the 24-hUP collection. Of 149 urine samples, only 39% were collected properly and were used for analysis. Results: The sensitivity and specificity of a ≥2+ dipstick test result to detect 0.50 g or greater 24-hUP were 56-% to 80% and 67% to 92%, respectively. The agreement of the urine dipstick test values and the magnitude of 24-hUP was fair (κ = 0.23-0.32). The correlation between the S-UPCI and the 24-hUP was 0.83 (P < 0.0001), and that of the 24-hour UPCI and the 24-hUP was 1 (P < 0.0001). Using 24-hUP 2 g/d or less, the bias ±1.96 SD of the difference of S-UPCI and 24-hUP was 0.23 (SD, 0.96) g. Conclusions: A ≥2+ dipstick test is relatively sensitive to detect significant proteinuria, but it is poorly correlated with quantitative 24-hUP. The S-UPCI and the 24-hUP can be used interchangeably for follow-up in lupus nephritis patients with proteinuria of less than 2 g/d. Copyright © 2011 Lippincott Williams & Wilkins. |
| บรรณานุกรม | : |
Chotayaporn T. , Kasitanon N. , Sukitawut W. , Louthrenoo W. . (2554). Comparison of proteinuria determination by urine dipstick, spot urine protein creatinine index, and urine protein 24 hours in lupus patients.
เชียงใหม่ : มหาวิทยาลัยเชียงใหม่ . Chotayaporn T. , Kasitanon N. , Sukitawut W. , Louthrenoo W. . 2554. "Comparison of proteinuria determination by urine dipstick, spot urine protein creatinine index, and urine protein 24 hours in lupus patients".
เชียงใหม่ : มหาวิทยาลัยเชียงใหม่ . Chotayaporn T. , Kasitanon N. , Sukitawut W. , Louthrenoo W. . "Comparison of proteinuria determination by urine dipstick, spot urine protein creatinine index, and urine protein 24 hours in lupus patients."
เชียงใหม่ : มหาวิทยาลัยเชียงใหม่ , 2554. Print. Chotayaporn T. , Kasitanon N. , Sukitawut W. , Louthrenoo W. . Comparison of proteinuria determination by urine dipstick, spot urine protein creatinine index, and urine protein 24 hours in lupus patients. เชียงใหม่ : มหาวิทยาลัยเชียงใหม่ ; 2554.
|
