| ชื่อเรื่อง | : | Wall bracing test results for 3.8 and 5.5 mm thick hydroline connected to pine and unseasoned timber framing members for Australian Particleboard Research Institute |
| นักวิจัย | : | McDowall, Colin G. |
| คำค้น | : | Particle board Testing. , Wooden-frame buildings Testing. , Wall panels Testing. , 090503 Construction Materials. , 860504 Reconstituted Timber Products (e.g. Chipboard, Particleboard). , Research report |
| หน่วยงาน | : | Central Queensland University, Australia |
| ผู้ร่วมงาน | : | - |
| ปีพิมพ์ | : | 2529 |
| อ้างอิง | : | http://hdl.cqu.edu.au/10018/985943 |
| ที่มา | : | Australian Particleboard Research Centre 1986, Wall bracing test results for 3.8 and 5.5 mm thick hydroline connected to pine and unseasoned timber framing members for Australian Particleboard Research Institute, a report prepared by CG McDowall, CIAE, Rockhampton, Qld. http://hdl.cqu.edu.au/10018/985943 |
| ความเชี่ยวชาญ | : | - |
| ความสัมพันธ์ | : | ACQUIRE [electronic resource] : Central Queensland University Institutional Repository. |
| ขอบเขตของเนื้อหา | : | - |
| บทคัดย่อ/คำอธิบาย | : | "This Report presents racking results obtained for 24 tests, 12 being performed on 3.8 mm thick particleboard sheathing and 12 on 5.5 mm thick sheathing. The 3.8 mm thick sheathing was connected by nailing only to 75 x 38 mm x F11 unseasoned hardwood framing and 70 x 45 mm x F8 Radiata pine framing. Panels were 2.7 m long x 2.4 m high with studs spaced at 450 mm centres. The 5.5 mm thick sheathing was connected by nailing only to 75 x 50 mm x F11 unseasoned hardwood framing and 90 x 45 mm x F8 Radiata pine framing. Panels were 2.4 m long x 2.4 m high with studs spaced a t 600 mm centres. The particleboard was a High Moisture Resistant (HMR) board tradenamed Hydroline and supplied by Pyneboard."--p. (ii). |
| บรรณานุกรม | : |
McDowall, Colin G. . (2529). Wall bracing test results for 3.8 and 5.5 mm thick hydroline connected to pine and unseasoned timber framing members for Australian Particleboard Research Institute.
กรุงเทพมหานคร : Central Queensland University, Australia. McDowall, Colin G. . 2529. "Wall bracing test results for 3.8 and 5.5 mm thick hydroline connected to pine and unseasoned timber framing members for Australian Particleboard Research Institute".
กรุงเทพมหานคร : Central Queensland University, Australia. McDowall, Colin G. . "Wall bracing test results for 3.8 and 5.5 mm thick hydroline connected to pine and unseasoned timber framing members for Australian Particleboard Research Institute."
กรุงเทพมหานคร : Central Queensland University, Australia, 2529. Print. McDowall, Colin G. . Wall bracing test results for 3.8 and 5.5 mm thick hydroline connected to pine and unseasoned timber framing members for Australian Particleboard Research Institute. กรุงเทพมหานคร : Central Queensland University, Australia; 2529.
|