ridm@nrct.go.th   ระบบคลังข้อมูลงานวิจัยไทย   รายการโปรดที่คุณเลือกไว้

Automated control technique for a single phase dynamic voltage restorer

หน่วยงาน Central Queensland University, Australia

รายละเอียด

ชื่อเรื่อง : Automated control technique for a single phase dynamic voltage restorer
นักวิจัย : Perera, Kasuni. , Salomonsson, Daniel. , Atputharajah, Arulampalam. , Alahakoon, Sanath.
คำค้น : Electromotive force. , TBA. , TBA. , TBA. , Electric power distribution. , Energy storage. , Electrical engineering. , Custom power device -- DVR -- Voltage sag
หน่วยงาน : Central Queensland University, Australia
ผู้ร่วมงาน : -
ปีพิมพ์ : 2549
อ้างอิง : http://hdl.cqu.edu.au/10018/62701
ที่มา : Perera, K, Salomonsson, D, Atputharajah, A & Alahakoon, S 2006, 'Automated control technique for a single phase Dynamic Voltage Restorer' in 2nd International Conference on Information and Automation, 2006. ICIA 2006, 14-17 Dec., Colombo, Sri Lanka, IEEE, Piscataway, NJ, http://dx.doi.org/10.1109/ICINFA.2006.374153
ความเชี่ยวชาญ : -
ความสัมพันธ์ : 2nd International Conference on Information and Automation, (ICIA 2006), 14-17 December 2006, Colombo, Sri Lanka. Piscataway, NJ : IEEE, 2006. p. 6 pages Refereed1424405556 , ACQUIRE [electronic resource] : Central Queensland University Institutional Repository.
ขอบเขตของเนื้อหา : -
บทคัดย่อ/คำอธิบาย :

The Dynamic Voltage Restorer (DVR) is a commercially available, popular device to eliminate voltage sags and swells in the distribution lines. Its basic function is to inject the voltage difference (difference between the pre-sag and sag voltage) to the power line and maintains the pre-sag voltage condition in the load side. Different control strategies are available depending on the compensation technique used for compensation. A new control strategy for the single-phase voltage sags based on in-phase compensation technique is described in this paper. In the designed control, the DVR initially tracks the phase angle of the supply voltage and produce a reference voltage signal with the rated load voltage magnitude. If any phase jump occurred at the supply voltage, phase angle of the reference voltage signal is adjusted slowly to track the phase angle of the supply voltage. The difference between the reference and measured voltage is injected by the DVR. Therefore with this DVR control technique, the load will not experience any phase jump or dip. The simulation was carried out using EMTDC/PSCAD software and the results show a very good level of compensation for different voltage sags.

บรรณานุกรม :
Perera, Kasuni. , Salomonsson, Daniel. , Atputharajah, Arulampalam. , Alahakoon, Sanath. . (2549). Automated control technique for a single phase dynamic voltage restorer.
    กรุงเทพมหานคร : Central Queensland University, Australia.
Perera, Kasuni. , Salomonsson, Daniel. , Atputharajah, Arulampalam. , Alahakoon, Sanath. . 2549. "Automated control technique for a single phase dynamic voltage restorer".
    กรุงเทพมหานคร : Central Queensland University, Australia.
Perera, Kasuni. , Salomonsson, Daniel. , Atputharajah, Arulampalam. , Alahakoon, Sanath. . "Automated control technique for a single phase dynamic voltage restorer."
    กรุงเทพมหานคร : Central Queensland University, Australia, 2549. Print.
Perera, Kasuni. , Salomonsson, Daniel. , Atputharajah, Arulampalam. , Alahakoon, Sanath. . Automated control technique for a single phase dynamic voltage restorer. กรุงเทพมหานคร : Central Queensland University, Australia; 2549.