| ชื่อเรื่อง | : | Feasibility of hybrid cooling system in a thermal power plant |
| นักวิจัย | : | Williams, Chris R. , Rasul, Mohammad. |
| คำค้น | : | Process control. , Applied research. , 850601 Energy Services and Utilities. , 850603 Energy Systems Analysis. , 850699 Energy Storage, Distribution and Supply not elsewhere classified. , 090407 Process Control and Simulation. , 090607 Power and Energy Systems Engineering (excl. Renewable Power) , Power-plants , Electric engineering. , Water consumption. , Power-plants , Power station -- Cooling -- Sustainable water consumption -- Hybrid cooling |
| หน่วยงาน | : | Central Queensland University, Australia |
| ผู้ร่วมงาน | : | - |
| ปีพิมพ์ | : | 2551 |
| อ้างอิง | : | http://hdl.cqu.edu.au/10018/28599 , cqu:4386 |
| ที่มา | : | Williams, C R & Rasul, M 2008, "Feasibility of hybrid cooling system in a thermal power plant", Proceedings of the 3rd IASME and WSEAS International Conference on Eenergy and Environment, 23-25 February 2008, Cambridge, UK, pp.124-129. |
| ความเชี่ยวชาญ | : | - |
| ความสัมพันธ์ | : | Proceedings of the 3rd IASME/WSEAS international conference on energy and environment, (EE'08), 23-25 February, 2008, Cambridge, UK. Greece. : WSEAS Press, 2008. p. 124-129 6 pages Refereed 9789606766466 , ACQUIRE [electronic resource] : Central Queensland University Institutional Repository. |
| ขอบเขตของเนื้อหา | : | - |
| บทคัดย่อ/คำอธิบาย | : | The feasibility of introducing a hybrid cooling system in a thermal power plant is investigated with an aim to reduce water use with a minimum impact on plant performance. A number of cooling systems have been modelled including existing evaporative cooling system taking into account of a wide variety of ambient conditions at full load. Water consumption and plant performance for all cooling options considered are calculated and compared. The results show that a significant amount of water can be conserved with a minimal impact on plant performance by implementing a hybrid cooling system in opposed to evaporative cooling tower. This study also reveals that, although a significant reduction in water use with minimum effect on plant performance is possible with hybrid cooling, it is not a financially viable option. |
| บรรณานุกรม | : |
Williams, Chris R. , Rasul, Mohammad. . (2551). Feasibility of hybrid cooling system in a thermal power plant.
กรุงเทพมหานคร : Central Queensland University, Australia. Williams, Chris R. , Rasul, Mohammad. . 2551. "Feasibility of hybrid cooling system in a thermal power plant".
กรุงเทพมหานคร : Central Queensland University, Australia. Williams, Chris R. , Rasul, Mohammad. . "Feasibility of hybrid cooling system in a thermal power plant."
กรุงเทพมหานคร : Central Queensland University, Australia, 2551. Print. Williams, Chris R. , Rasul, Mohammad. . Feasibility of hybrid cooling system in a thermal power plant. กรุงเทพมหานคร : Central Queensland University, Australia; 2551.
|