Interdevice baseline signal magnitude variability of the ActivPAL3 activity monitor

หน่วยงาน Central Queensland University, Australia

รายละเอียด

ชื่อเรื่อง : Interdevice baseline signal magnitude variability of the ActivPAL3 activity monitor
นักวิจัย : Stanton, Robert. , Vandelanotte, Corneel. , Duncan, Mitch J.
คำค้น : LIBRARY OF CONGRESS NEEDED , Applied research. , 920401 Behaviour and Health. , 920412 Preventive Medicine. , 111712 Health Promotion. , 111716 Preventive Medicine. , 110604 Sports Medicine. , Activity monitor -- Accelerometer -- Motion sensor -- Calibration , Journal Article. Refereed, Scholarly Journal
หน่วยงาน : Central Queensland University, Australia
ผู้ร่วมงาน : -
ปีพิมพ์ : 2557
อ้างอิง : http://hdl.cqu.edu.au/10018/1023825
ที่มา : Stanton, R, Vandelanotte, C & Duncan, MJ 2014, 'Interdevice baseline signal magnitude variability of the ActivPAL3 activity monitor', Gait & Posture, vol. 39, no. 1, pp. 618-620, http://dx.doi.org/10.1016/j.gaitpost.2013.06.013
ความเชี่ยวชาญ : -
ความสัมพันธ์ : Gait & posture. Netherlands : Elsevier, 2014. Vol. 39, no. 1 (2014), p. 618-620 3 pages Refereed 0966-6362 , ACQUIRE [electronic resource] : Central Queensland University Institutional Repository.
ขอบเขตของเนื้อหา : -
บทคัดย่อ/คำอธิบาย :

The aim of this study was to evaluate the interdevice variability in baseline signal magnitude of the ActivPAL3 (PALTechnologies, Glasgow, UK) activity monitor. Twenty consecutively numbered ActivPAL3 triaxial physical activity monitors were assessed for baseline signal magnitudes oriented in the X(vertical standing), Y (side lying), and Z (lying flat) planes. Data was recorded for 60 s in each orientation and the three orthogonal axes were analysed for baseline signal magnitude each orientation. Our batch of devices demonstrated approximately 6.6% difference in raw acceleration calibration values comparedto manufacturer specifications. Analysis of interdevice variability revealed three devices which exhibited baseline signal variability greater than 1.96 SD of the group mean. The impact of interdevice variability in baseline signal magnitude on data collection is unknown, however, supports the argument in the literature for the systematic checking of interdevice variability as routine maintenance.

บรรณานุกรม :
Stanton, Robert. , Vandelanotte, Corneel. , Duncan, Mitch J. . (2557). Interdevice baseline signal magnitude variability of the ActivPAL3 activity monitor.
    กรุงเทพมหานคร : Central Queensland University, Australia.
Stanton, Robert. , Vandelanotte, Corneel. , Duncan, Mitch J. . 2557. "Interdevice baseline signal magnitude variability of the ActivPAL3 activity monitor".
    กรุงเทพมหานคร : Central Queensland University, Australia.
Stanton, Robert. , Vandelanotte, Corneel. , Duncan, Mitch J. . "Interdevice baseline signal magnitude variability of the ActivPAL3 activity monitor."
    กรุงเทพมหานคร : Central Queensland University, Australia, 2557. Print.
Stanton, Robert. , Vandelanotte, Corneel. , Duncan, Mitch J. . Interdevice baseline signal magnitude variability of the ActivPAL3 activity monitor. กรุงเทพมหานคร : Central Queensland University, Australia; 2557.