Feasibility study of a bi-directional centrifugal pump for DBT class 45 CST gearbox used in underground coal mining operation

หน่วยงาน Central Queensland University, Australia

รายละเอียด

ชื่อเรื่อง : Feasibility study of a bi-directional centrifugal pump for DBT class 45 CST gearbox used in underground coal mining operation
นักวิจัย : Buckett, Cameron. , Rasul, Mohammad. , Khan, Mohammad Masud Kamal.
คำค้น : Centrifugal pumps. , Resourcing Queensland , Mechanical engineering. , Coal mines and mining. , 650102 Coal , 650401 Exploration , 290501 Mechanical Engineering , 290701 Mining Engineering , Centrifugal pump -- Coal mining -- Gearbox
หน่วยงาน : Central Queensland University, Australia
ผู้ร่วมงาน : -
ปีพิมพ์ : 2550
อ้างอิง : http://hdl.cqu.edu.au/10018/12422 , , cqu:2687
ที่มา : Buckett, C, Rasul, MG & Khan, MMK 2007, 'Feasibility study of a bi-directional centrifugal pump for DBT class 45 CST gearbox used in underground coal mining operation', in: Jacobs, Peter, McIntyre, Tim, Cleary, Matthew, Buttsworth, David, Mee, David, Clements, Rose, Morgan, Richard and Lemckert, Charles 16th Australasian Fluid Mechanics Conference (AFMC), Gold Coast, Queensland, Australia, 3-7 December, 2007.
ความเชี่ยวชาญ : -
ความสัมพันธ์ : Proceedings of the 16th Australiasian Fluid Mechanics Conference Brisbane, Qld : University of Queensland, School of Engineering, 2007. p.1369-1373 5 pages Refereed 9781864998948 , aCQUIRe [electronic resource] : Central Queensland University Institutional Repository.
ขอบเขตของเนื้อหา : -
บทคัดย่อ/คำอธิบาย :

This paper presents a feasibility study of using a bi-directional centrifugal pump into DBT’s Series 45 CST gearbox. The suitability of other pumps for cooling and the design of a new symmetrical centrifugal pump that would be suited to the series 45 CST gearbox have been reviewed with financial versus functionality and usability. The analysis and results of this study indicate that by introducing the newly designed bi-directional pump, DBT may save over $370k in production costs over 10 years. This equates to a savings of $1850 per gearbox which is about a 26% saving on the current set-up, and thus bi-directional pump is reasonably feasible.

บรรณานุกรม :
Buckett, Cameron. , Rasul, Mohammad. , Khan, Mohammad Masud Kamal. . (2550). Feasibility study of a bi-directional centrifugal pump for DBT class 45 CST gearbox used in underground coal mining operation.
    กรุงเทพมหานคร : Central Queensland University, Australia.
Buckett, Cameron. , Rasul, Mohammad. , Khan, Mohammad Masud Kamal. . 2550. "Feasibility study of a bi-directional centrifugal pump for DBT class 45 CST gearbox used in underground coal mining operation".
    กรุงเทพมหานคร : Central Queensland University, Australia.
Buckett, Cameron. , Rasul, Mohammad. , Khan, Mohammad Masud Kamal. . "Feasibility study of a bi-directional centrifugal pump for DBT class 45 CST gearbox used in underground coal mining operation."
    กรุงเทพมหานคร : Central Queensland University, Australia, 2550. Print.
Buckett, Cameron. , Rasul, Mohammad. , Khan, Mohammad Masud Kamal. . Feasibility study of a bi-directional centrifugal pump for DBT class 45 CST gearbox used in underground coal mining operation. กรุงเทพมหานคร : Central Queensland University, Australia; 2550.