| ชื่อเรื่อง | : | A silicon nitride ISFET based immunosensor for Ag85B detection of tuberculosis |
| นักวิจัย | : | Saengdee P. , Chaisriratanakul W. , Bunjongpru W. , Sripumkhai W. , Srisuwan A. , Hruanun C. , Poyai A. , Phunpae P. , Pata S. , Jeamsaksiri W. , Kasinreak W. , Promptmas C. |
| คำค้น | : | - |
| หน่วยงาน | : | มหาวิทยาลัยเชียงใหม่ |
| ผู้ร่วมงาน | : | - |
| ปีพิมพ์ | : | 2559 |
| อ้างอิง | : | 00032654 , 2-s2.0-84990061917 , 10.1039/c6an00568c , https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84990061917&origin=inward , http://cmuir.cmu.ac.th/jspui/handle/6653943832/41426 |
| ที่มา | : | - |
| ความเชี่ยวชาญ | : | - |
| ความสัมพันธ์ | : | - |
| ขอบเขตของเนื้อหา | : | - |
| บทคัดย่อ/คำอธิบาย | : | © 2016 The Royal Society of Chemistry. A silicon nitride Ion Sensitive Field Effect Transistor (ISFET) based immunosensor was developed as a low-cost and label-free electrical detection for the detection of antigen 85 complex B (Ag85B). The sensing membrane of the ISFET was modified with 3-aminopropyltriethoxysilane (APTES) followed by glutaraldehyde (GA), yielding an aldehyde-terminated surface. This group is available for immobilization of a monoclonal antibody against a recombinant Ag85B protein (anti-Ag85B antibody). The optimal concentration for anti-Ag85B antibody immobilization onto the modified ISFET was 100 μg ml -1 . This optimal condition provided the maximal binding capability and minimal non-specific background signal. The binding event between the recombinant Ag85B antigen and anti-Ag85B antibody on the ISFET surface is presented by monitoring the gate potential change at a constant drain current. The dose response for the recombinant Ag85B protein showed a linear response between 0.12 and 1 μg ml -1 without significant interference from other recombinant proteins. The analytical imprecision (CV%) and accuracy of this Ag85B protein biosensor were 9.73-10.99% and 95.29%, respectively. In addition, an irrelevant antibody and other recombinant proteins were employed as a negative control to demonstrate the non-specific interaction of the antigen and antibody. The success of this immunosensor system for Ag85B protein detection facilitates the construction of a promising device which can shorten the turnaround time for the diagnosis of tuberculosis compared to a standard culture method. Furthermore, this device could also be applied for real-time growth monitoring of Mycobacterium tuberculosis in a mycobacterial culture system. |
| บรรณานุกรม | : |
Saengdee P. , Chaisriratanakul W. , Bunjongpru W. , Sripumkhai W. , Srisuwan A. , Hruanun C. , Poyai A. , Phunpae P. , Pata S. , Jeamsaksiri W. , Kasinreak W. , Promptmas C. . (2559). A silicon nitride ISFET based immunosensor for Ag85B detection of tuberculosis.
เชียงใหม่ : มหาวิทยาลัยเชียงใหม่ . Saengdee P. , Chaisriratanakul W. , Bunjongpru W. , Sripumkhai W. , Srisuwan A. , Hruanun C. , Poyai A. , Phunpae P. , Pata S. , Jeamsaksiri W. , Kasinreak W. , Promptmas C. . 2559. "A silicon nitride ISFET based immunosensor for Ag85B detection of tuberculosis".
เชียงใหม่ : มหาวิทยาลัยเชียงใหม่ . Saengdee P. , Chaisriratanakul W. , Bunjongpru W. , Sripumkhai W. , Srisuwan A. , Hruanun C. , Poyai A. , Phunpae P. , Pata S. , Jeamsaksiri W. , Kasinreak W. , Promptmas C. . "A silicon nitride ISFET based immunosensor for Ag85B detection of tuberculosis."
เชียงใหม่ : มหาวิทยาลัยเชียงใหม่ , 2559. Print. Saengdee P. , Chaisriratanakul W. , Bunjongpru W. , Sripumkhai W. , Srisuwan A. , Hruanun C. , Poyai A. , Phunpae P. , Pata S. , Jeamsaksiri W. , Kasinreak W. , Promptmas C. . A silicon nitride ISFET based immunosensor for Ag85B detection of tuberculosis. เชียงใหม่ : มหาวิทยาลัยเชียงใหม่ ; 2559.
|